A management system certificate is valid for three years, but it stays in force only if the organization passes a surveillance audit in the second and third year and a recertification audit before it expires. Surveillance is not a repeat of the initial audit but a check that the system continues to work and to improve.

Euro Standard CertificationThe ESCERT team Published
Updated
5 minread
Employee writing on a clipboard in a warehouse with tools hanging on the wall

Why does the certificate require surveillance?

Accredited certification bodies work to ISO/IEC 17021-1, which obliges them to maintain certification through periodic audits. The logic is simple: the certificate attests that the management system meets the standard and works - and that can only be claimed if someone checks it regularly.

That is why the three-year certificate is a cycle, not a one-off event: an initial audit in two stages, two surveillance audits and recertification. On certificates issued by CERTIND S.A., successful surveillance is marked with an annual visa, and the current status is checked with the certification body and in the global IAF CertSearch database. How to do the check - in the article How to check whether an ISO certificate is valid.

  1. Year 1

    Stage 1 and Stage 2 of the initial audit, the certification decision and the issue of the certificate for three years.

  2. Within 12 months

    The first surveillance audit - no later than 12 months from the certification decision date.

  3. Year 3

    The second surveillance audit - at least once a calendar year, except in the recertification year.

  4. Before expiry

    Recertification audit and a new decision; the new certificate continues the previous cycle.

What does the auditor check at a surveillance audit?

A surveillance audit is shorter than the initial one and does not necessarily cover the whole system. The standard does, however, define what it must include:

  • Internal audits and management reviewWhether they were carried out according to the programme, with competent auditors and with decisions that are being implemented.
  • Actions on previous nonconformitiesWhether the causes were removed, not just the symptoms - a recurrence upgrades the nonconformity to major.
  • ComplaintsHow complaints from customers and other interested parties are received and handled.
  • Effectiveness and objectivesWhether the system achieves its objectives and whether the planned improvements are progressing.
  • Operational control and changesWhether process control continues; whether changes in the activity, sites, staff and legislation are reflected.
  • Use of the certificate and the markWhether certification is cited correctly and the certification mark is used properly - within the scope and without misleading.

The auditor also selects parts of the system for more detailed checking - different ones each year, so that the whole system is reviewed over the three years. The processes with nonconformities from the previous audit are always among them.

Recertification: what is different?

The recertification audit is planned and conducted so that the decision is made before the certificate expires. It evaluates the whole management system and its effectiveness over the entire past cycle: the results of the surveillance audits, the development of the system, changes in the organization and whether it continues to meet the standard. In the event of significant changes - a new site, a new activity, a new version of the standard - a Stage 1 may also be needed.

Nonconformities at recertification are treated as at the initial audit: a major one must be resolved and verified before the decision. When everything is in order, the new certificate is issued for three years, and its term continues the previous cycle.

Surveillance auditChecking maintenance

Part of the system, the mandatory elements under the standard and the actions on previous findings.

RecertificationChecking the whole cycle

The whole system, its effectiveness over the three years and readiness for the next cycle.

What happens after a missed or failed audit?

A certificate does not expire quietly. ISO/IEC 17021-1 gives the certification body three tools: suspension, withdrawal and reduction of scope. They apply when the system persistently or seriously fails to meet the requirements, when the organization does not allow surveillance audits at the required frequency, or when it requests suspension itself.

  • Suspension

    The certificate is temporarily invalid and the organization must not present it as current. If the cause is not removed within the time set by the certification body - usually no more than six months - withdrawal or reduction of scope follows.

  • Expired certificate

    If recertification is not completed before expiry, the certificate lapses. Up to six months afterwards it can be restored if the outstanding activities are completed; otherwise at least a new Stage 2 is conducted.

  • Reduced scope

    When part of the activities no longer meets the requirements, the certification body may remove those activities from the scope of the certificate instead of withdrawing it altogether.

For customers and contracting authorities who check the certificate, the status “suspended” or “withdrawn” is visible with the certification body and in IAF CertSearch - which is why a missed surveillance audit has consequences beyond the document itself.

How to keep the certificate valid: a calendar

  1. 1Note the dates

    The certification decision date and the term of the certificate determine the whole calendar. The first surveillance audit is within 12 months of the decision.

  2. 2Plan the internal audit and the management review

    Every year, before the surveillance audit - these are the first things the auditor checks.

  3. 3Close nonconformities with a root-cause analysis

    A repeated nonconformity at surveillance is the most common path to a major nonconformity and suspension.

  4. 4Notify the certification body of changes

    New sites, activities, significant changes in staff or the system - they affect the scope and the planning of the audit.

  5. 5Start recertification in time

    Request the audit so that the decision is made before expiry. You receive a quote for recertification within two hours during working hours.

What the types of nonconformity mean and how to respond to them - in the article Nonconformities in a certification audit; the whole process - in Certification process.

Surveillance audit and recertificationQuote within two hours during working hoursGet a quote

Questions about surveillance audits and recertification

How often are surveillance audits carried out?

At least once a calendar year, except in the recertification year. The first surveillance audit after initial certification must be carried out no later than 12 months from the certification decision date (ISO/IEC 17021-1).

What is checked at a surveillance audit?

Mandatory: the internal audits and the management review, the actions on nonconformities from the previous audit, complaint handling, the effectiveness of the system against its objectives, progress on improvements, operational control, changes and the use of the certificate and the mark. Individual processes are selected for more detailed checking.

What happens if I miss the surveillance audit?

The certification body may suspend the certificate - it becomes temporarily invalid. If surveillance is not carried out within the time set by the certification body, the certificate is withdrawn or its scope is reduced. The status is visible with the certification body and in IAF CertSearch.

Can an expired certificate be restored?

Yes, within six months of expiry, if the outstanding recertification activities are completed. After that period at least a new Stage 2 audit is conducted. The term of the restored certificate follows the previous cycle.

Is recertification shorter than initial certification?

Usually Stage 1 is not needed, except in the event of significant changes in the organization or the system. The audit evaluates the whole system and its effectiveness over the past cycle, and nonconformities are treated as at the initial audit.

Free preliminary assessment and quote

A certificate that stays valid

Describe your activity, sites and number of employees - you will receive a quote for a surveillance audit or recertification with the scope, the audit duration and the price with all costs included.